Introduction 10
ACCUM
is only displayed if the accumulator is enabled.
3. Press , VIEW is displayed.
4. Press to view the current accumulator value.
5. While the accumulator value is displayed, press to print the value.
The format of the print ouput can be configured using accumulator print
format. See Section 7.0.
1.4.13 Clear the Accumulator
1. Press to enter the user setup mode, AUDIT is displayed.
2. Press or until
ACCUM is displayed.
3. Press , then press or until
CLR Y is displayed.
4. Press to clear the accumulator,
CLEAR will display briefly and
display returns to
CLR Y.
5. Press to return to the weigh mode.
The PRINT key only performs one accumulation. Weight must return to
zero below the configured threshold value before another accumulation
is allowed.
Threshold is configured in the setup menu, see Section 3.2.3.
1.4.14 Display Tare
When a stored Tare value is displayed, the Gross and Net LEDs will be off and the
will be lit. To display a stored tare:
1. Press .
2. Press to
TARE and press to view the current tare value.
3. Press twice to return to weighing mode.
If there is no tare in the system, the value displayed will be zero and the Gross and
Net LED will be turned off.
See the Technical Service Manual (PN 158387) for more information pertaining to
the regulatory mode of operation.
Note
PRINT
Note
MENU
TARE
MENU
Note
MENU
MENU