44 880 Technical/Service Manual
COM Menu
Parameter Choices Description
TRIGGE COMAND Setting Trigger to command allows opration of EDP
commands and can print.
STRLFT Stream Legal for Trade data – data is updated at the configur
ed display update rate.
STRIND Stream Industrial scale data – data is upda
ted at the configured sample rate.
REMOTE Configures the port to operate as a serial scale input. See “Menu St
ructure if
TRIGGE is set to REMOTE” below. (Not available in USBCOM)
When in STRLFT, STRIND and REMOTE, if the COM port is set to TYPE = RS485, the
port will not stream data, and canno
t be used in a local/remote application. See
Section 10.6.3.
BAUD 9600
19200
28800
38400
57600
115200
1200
2400
4800
Port baud rate. (Not availa
ble in USBCOM)
BITS 8NONE
7EVEN
7ODD
Port data bits and parity. (Not availa
ble in USBCOM)
STOP B 1
2
Stop Bits – selects the number of stop bits transmitted and the number of stop bits
expected to be received by the port. (Not available in USBCOM)
TERMIN CR/LF
CR
Termination – selects the ter
mination character(s) for data sent from the port.
ECHO ON
OFF
Specifies whether characters received by the port are echoed back to the sending
unit.
RESPNS ON
OFF
Response – specifies whether the port transmits replies to serial commands
EOLDLY 000000 End of Line Delay - specifies, in 0.1 second
intervals, the delay between transmitted
lines of data.
TYPE 232
485
Specifies the protocol for the COM port. (Not available in USBCOM)
ADDRES 0-255 If TYPE is 485, specifies the RS-485 address. (Not available in USBCOM)
PRNMSG OFF
ON
Print message – displays a messa
ge when a print is transmitted on this port.
SFMT <2><P><W7.>
<U><M><S>
<CR><LF>
Stream format – specifies the stream format used for streaming output of scale data
(TRIGGE=STRLFT or STRIND) or specifies the expected input for a serial scale
(TRIGGE=REMOTE).
Menu Structure if TRIGGE is set to REMOTE
TRIGGE REMOTE Configures the port to operate as a serial scale input.
BAUD 9600
19200
28800
38400
57600
115200
1200
2400
4800
Port baud rate.
Table 3-11. COM and USBCOM Menu Parameters