3.2.15 Analog Output Menu
The ALGOUT menu is used only if the analog output option is installed. If the analog output option is installed,
configure all other indicator functions and calibrate the indicator before configuring the analog output. See
Section 10.11 on page 108 for analog output calibration procedures.
SETUP
........
....
ALGOUT
....
number
TWSPAN
OFF
ON
MAXNEGMINNEG
OFF
ON
ERRACT
FULLSC
ZEROSC
HOLD
OUTPUT
0-10V
0-20MA
4-20MA
MODE
GROSS
NET
MAX
10000
number
TWZERO
number
MIN
number
0
Figure 3-23. Analog Output Menu
Table 3-17. Analog Output Menu Parameters
ALG OUT Menu
Parameter Choices Description
Level 2 submenus
MODE GROSS
NET
Defines if the output follows the
GROSS or NET weight.
OUTPUT 0-10V
0-20MA
4-20MA
Selects whether the analog output supplies voltage (0–10
V), current (0-20mA),
or current (4-20mA).
ERRACT FULLSC
HOLD
ZEROSC
Error action. Specifies how the analog output
responds to system error conditions.
Possible values are:
FULLSC: Set to full value (10 V or 2
0 mA, depending on output setting)
HOLD: Hold current value
ZEROSC: Set to zero value (0 V or 4 mA, depending on output setting)
MIN 0.000000
number
Specifies the minimum weight value tracked by the
analog output. Specify a value in the range
0–999999.
MIN NEG OFF
ON
Set to ON if the MIN value is negative.
MAX 10000.00
number
Specifies the maximum weight value tracked by the analog output. Speci
fy a value in the range
0–999999.
MAX NEG OFF
ON
Set to ON if the MAX value is negative.
TWZERO 000000
number
Calibrate zero. Adjust the analog output zero calibration. See Section 10.11 on page 108.
TWSPAN 000000
number
Calibrate span. Adjust the analog
output span calibration. See Section 10.11 on page 108