Rice-lake 880 Performance Series Indicator/Controller Techni Manual de usuario Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
Introduction 1
About This Manual
This manual is intended for use by service technicians responsible for installing and servicing 880 digital weight
indicators.
This manual applies to indicators using Version 1.01 of the 88
0
firmware.
Configuration and calibration of the indicator
can be accomplished using the indicator front panel keys, the EDP
command set, or Version 3.0 or later of the Revolution
®
configuration utility. See Section 3.1 on page 26 for
information about configuration methods.
Authorized distributors and their employees can view or download this manual from the Rice Lake
Weighing Systems website at
www.ricelake.com.
An Operator
s Manual is included with the indicator and provides basic operating instructions for users of the 880.
Please leave the Operators Manual with the indicator when installation and configuration are complete.
1.0 Introduction
The 880 is a single-channel digital weight indicator housed in a panel mount enclosure. The front panel bezel can
be sealed to a NEMA 4X/IP65 rating. The front panel consists of a 6-button keypad and a 6-digit, 14-segment LED
display.
Features include:
Drives up to 8 350o
r
16 700 load cells
Supports four and six wire
load cell connections
Four configurable digital inputs or outputs
Full duplex RS-232 or half duplex RS-485 communications at up to 115200 bp
s
Ethernet TCP/IP interface for 10Base-T/100Base-TX network communications
USB interface for host (type A connection) or device
Expansion slot for one option card
Optional DeviceNet
interface for communications network with Allen-Bradley
®
controllers
1
Optional Ethernet/IP interface for Allen-Bradley PLC and other Ethernet/IP master devices
3
Optional Profibus
®
DP interface
2
Optional Modbus TCP interface
Optional Profinet Interface
Optional analog output module provides 0–10 VDC, 0-
20mA or 4–20 mA tracking of gross or net
weight values
Optional four channel relay module, dr
y connect 3A @ 115VAC, 3A @ 30VDC
Available in 115 VAC and 230 VAC versions
1. DeviceNet
is a trademark of the Open DeviceNet Vendor Association.
2. Profibus
®
is a registered trademark of Profibus International.
3. EtherNet/IP
is a trademark of the Open DeviceNet Vendor Association.