Configuration 53
PCOUNT 1
1–65535
Preact learn interval. For setpoints with PREACT set to LEARN, specifies the number
of batches after which the preact value is recalculated. The default value, 1,
recalculates the preact value after every batch cycle.
RELNUM 1
1–20
For %REL setpoints, specifies the number of the r
elative setpoint. The target weight for
this setpoint is the percentage (specified on the VALUE parameter of the %REL
setpoint) of the target value of the relative setpoint
BATSEQ OFF
ON
Specifies whether the setpoint is used as a batch (ON) or continuo
us (OFF) setpoint.
CLRACM OFF
ON
Specify ON to clear the accumulator
when the setpoint is satisfied
CLRTAR OFF
ON
Specify ON to clear the tare when th
e setpoint is satisfied
PSHACM OFF
ON
ONQUIE
Specify ON to update the accumulator and perform a
print operation when the setpoint
is satisfied (uses the accumulator print format). Specify ONQUIE to update the
accumulator without printing.
PSHPRT OFF
ON
WAITSS
Specify ON to perform a print operation when the setpoint is satisfied; specify WAITSS
to
wait for standstill after setpoint is satisfied before printing.
For AUTJOG setpoints, it will print only once the previous setpoint is
satisfied. Instead of printing the setpoint print format, it will print the
GR
OSS or NET print format (depends on the type of the previous
setpoint).
PSHTAR OFF
ON
Specify ON to perform an acquire tare opera
tion when the setpoint is satisfied.
PSHTAR acquires the tare regardless of the value specified for the
REGULA parameter in the FEATUR men
u, and regardless of the
stability.
If two or more of the CLRxx
x and PSHxxx parameters are set on, the actions specified by those parameters
are performed in the following order when the setpoint is sa
tisfied: 1) clear accumulator; 2) clear tare; 3)
accumulate; 4) print; 5) acquire tare.
ACCESS ON
OFF
Specifies the access allowed to setpoint parameters sh
own in the new user menu.
ON: Values can be displayed and changed
OFF: Values can be displayed but
not changed
NAME 6ALPHA A six character alphanumeric name for the setpoint.
SLOT NONE
SLOT 0
SLOT 1
Lists all available digital I/O slots.
SLOT 0 – onboard DIO
SLOT 1 – Option card (if installed)
A slot will only appear if one or more of its individual bits are
configured as an output.
DIGOUT BIT 1-4 Lists all digital output bits available for the
specified SLOT. This parameter is used to
specify the digital output bit associated with this setpoint. Use the DIG I/O menu to
assign bit function to OUTPUT.
For continuous setpoints, the digital output becom
es active (low) when the condition is
met; for batch setpoints, the digital output is active until the setpoint condition is met.
SENSE NORMAL
INVERT
Specifies whether the state of the digital output associ
ated with this setpoint is inverted
when the setpoint is satisfied.
BRANCH 0
1-20
Specifies the setpoint number to which the batch se
quence is to branch if the current
setpoint is not satisfied upon initial evaluation.
The special value zero indicates that no branch is taken.
START 1
1–20
Specifies the starting se
tpoint number. Do not specify the number of the TIMER or
CONCUR setpoint itself. The TIMER or CONCUR setpoint begins when the starting
setpoint begins.
END 1
1–20
Specifies the ending setpoint number. Do not specify the number of the TIMER or
CONCUR setpoint itself. The TIMER or CONCUR setpoint stops when the ending
setpoint begins.
SETPTS Menu
Parameter Choices Description
Table 3-15. Setpoint Menu Parameters
Comentarios a estos manuales